| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| An unauthenticated remote attacker can exploit a denial-of-service vulnerability in the device's web server functionality by sending a specially crafted HTTP request with a malicious header, potentially causing the server to crash or become unresponsive. |
| An unauthenticated remote attacker can exploit input validation in cmd services of the devices, allowing them to disrupt system operations and potentially cause a denial-of-service. |
| An unauthenticated remote attacker can exploit insufficient input validation to write data beyond the bounds of a buffer, potentially leading to a denial-of-service condition for the devices. |
| An unauthenticated remote attacker could use a demo account of the portal to hijack devices that were created in that account by mistake. |
| Insufficient protection against brute-force and runtime manipulation in the local authentication component in Two App Studio Journey 5.5.6 on iOS allows local attackers to bypass biometric and PIN-based access control via repeated PIN attempts or dynamic code injection. |
| Improper Authentication vulnerability in Danfoss AKSM8xxA Series.This issue affects Danfoss AK-SM 8xxA Series prior to version 4.2 |
| DuraComm SPM-500 DP-10iN-100-MU
is vulnerable to a cross-site scripting attack. This could allow an attacker to prevent legitimate users from accessing the web interface. |
| Fuji Electric Smart EditorĀ is vulnerable to an out-of-bounds write, which may allow an attacker to execute arbitrary code. |
| An arbitrary code execution vulnerability exists in the git functionality of Truffle Security Co. TruffleHog 3.90.2. A specially crafted repository can lead to a arbitrary code execution. An attacker can provide a malicious respository to trigger this vulnerability. |
| Fuji Electric Smart Editor is vulnerable to a stack-based buffer overflow, which may allow an attacker to execute arbitrary code. |
| In specific circumstances, due to a weakness in the Pseudo Random Number Generator (PRNG) that is used, it is possible for an attacker to predict the source port and query ID that BIND will use.
This issue affects BIND 9 versions 9.16.0 through 9.16.50, 9.18.0 through 9.18.39, 9.20.0 through 9.20.13, 9.21.0 through 9.21.12, 9.16.8-S1 through 9.16.50-S1, 9.18.11-S1 through 9.18.39-S1, and 9.20.9-S1 through 9.20.13-S1. |
| If a DHCPv4 client sends a request with some specific options, and Kea fails to find an appropriate subnet for the client, the `kea-dhcp4` process will abort with an assertion failure. This happens only if the client request is unicast directly to Kea; broadcast messages do not cause the problem.
This issue affects Kea versions 2.7.1 through 2.7.9, 3.0.0, and 3.1.0. |
| Under certain circumstances, BIND is too lenient when accepting records from answers, allowing an attacker to inject forged data into the cache.
This issue affects BIND 9 versions 9.11.0 through 9.16.50, 9.18.0 through 9.18.39, 9.20.0 through 9.20.13, 9.21.0 through 9.21.12, 9.11.3-S1 through 9.16.50-S1, 9.18.11-S1 through 9.18.39-S1, and 9.20.9-S1 through 9.20.13-S1. |
| If a `named` caching resolver is configured with `serve-stale-enable` `yes`, and with `stale-answer-client-timeout` set to `0` (the only allowable value other than `disabled`), and if the resolver, in the process of resolving a query, encounters a CNAME chain involving a specific combination of cached or authoritative records, the daemon will abort with an assertion failure.
This issue affects BIND 9 versions 9.20.0 through 9.20.10, 9.21.0 through 9.21.9, and 9.20.9-S1 through 9.20.10-S1. |
| A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V3.0). The affected application uses a Content Security Policy that allows unsafe script execution methods. This could allow an attacker to execute unauthorized scripts, potentially leading to cross-site scripting attacks. |
| A vulnerability has been identified in Altair Grid Engine (All versions < V2026.0.0). Affected products do not properly validate environment variables when loading shared libraries, allowing path hijacking through malicious library substitution.
This could allow a local attacker to execute arbitrary code with superuser privileges by manipulating the environment variable and placing a malicious library in the controlled path. |
| A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions), RUGGEDCOM ROX MX5000RE (All versions), RUGGEDCOM ROX RX1400 (All versions), RUGGEDCOM ROX RX1500 (All versions), RUGGEDCOM ROX RX1501 (All versions), RUGGEDCOM ROX RX1510 (All versions), RUGGEDCOM ROX RX1511 (All versions), RUGGEDCOM ROX RX1512 (All versions), RUGGEDCOM ROX RX1524 (All versions), RUGGEDCOM ROX RX1536 (All versions), RUGGEDCOM ROX RX5000 (All versions). Affected devices do not properly limit access through its Built-In-Self-Test (BIST) mode.
This could allow an attacker with physical access to the serial interface to bypass authentication and get access to a root shell on the device. |
| When an incoming DNS protocol message includes a Transaction Signature (TSIG), BIND always checks it. If the TSIG contains an invalid value in the algorithm field, BIND immediately aborts with an assertion failure.
This issue affects BIND 9 versions 9.20.0 through 9.20.8 and 9.21.0 through 9.21.7. |
| A vulnerability has been identified in SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 9), SIMATIC STEP 7 V18 (All versions), SIMATIC STEP 7 V19 (All versions < V19 Update 4), SIMATIC STEP 7 V20 (All versions < V20 Update 4), SIMATIC WinCC V17 (All versions < V17 Update 9), SIMATIC WinCC V18 (All versions), SIMATIC WinCC V19 (All versions < V19 Update 4), SIMATIC WinCC V20 (All versions < V20 Update 4), SIMOCODE ES V17 (All versions), SIMOCODE ES V18 (All versions), SIMOCODE ES V19 (All versions), SIMOCODE ES V20 (All versions), SIMOTION SCOUT TIA V5.4 (All versions), SIMOTION SCOUT TIA V5.5 (All versions), SIMOTION SCOUT TIA V5.6 (All versions < V5.6 SP1 HF7), SIMOTION SCOUT TIA V5.7 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SINAMICS Startdrive V19 (All versions), SINAMICS Startdrive V20 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Safety ES V19 (TIA Portal) (All versions), SIRIUS Safety ES V20 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions), SIRIUS Soft Starter ES V20 (TIA Portal) (All versions), TIA Portal Cloud V17 (All versions), TIA Portal Cloud V18 (All versions), TIA Portal Cloud V19 (All versions < V5.2.1.1), TIA Portal Cloud V20 (All versions < V5.2.2.2). Affected products do not properly sanitize stored security properties when parsing project files. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. |
| A vulnerability has been identified in Mendix SAML (Mendix 10.12 compatible) (All versions < V4.0.3), Mendix SAML (Mendix 10.21 compatible) (All versions < V4.1.2), Mendix SAML (Mendix 9.24 compatible) (All versions < V3.6.21). Affected versions of the module insufficiently enforce signature validation and binding checks. This could allow unauthenticated remote attackers to hijack an account in specific SSO configurations. |