| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| The program libraries (DLL) and binaries used by exos 9300 contain multiple hard-coded secrets. One notable example is the function "EncryptAndDecrypt" in the library Kaba.EXOS.common.dll. This algorithm uses a simple XOR encryption technique combined with a cryptographic key (cryptoKey) to transform each character of the input string. However, it's important to note that this implementation does not provide strong encryption and should not be considered secure for sensitive data. It's more of a custom encryption approach rather than a common algorithm used in cryptographic applications. The key itself is static and based on the founder's name of the company. The functionality is for example used to encrypt the user PINs before storing them in the MSSQL database. |
| An issue in H3C Magic M Device M2V100R006 allows a remote attacker to execute arbitrary code via the default password |
| Aptos Wisal payroll accounting before 7.1.6 uses hardcoded credentials in the Windows client to fetch the complete list of usernames and passwords from the database server, using an unencrypted connection. This allows attackers in a machine-in-the-middle position read and write access to personally identifiable information (PII) and especially payroll data and the ability to impersonate legitimate users with respect to the audit log. |
| A vulnerability classified as critical was found in NuCom NC-WR744G 8.5.5 Build 20200530.307. This vulnerability affects unknown code of the component Console Application. The manipulation of the argument CMCCAdmin/useradmin/CUAdmin leads to hard-coded credentials. The attack can be initiated remotely. The vendor was contacted early about this disclosure but did not respond in any way. |
| The CS5000 Fire Panel is vulnerable due to a hard-coded password that
runs on a VNC server and is visible as a string in the binary
responsible for running VNC. This password cannot be altered, allowing
anyone with knowledge of it to gain remote access to the panel. Such
access could enable an attacker to operate the panel remotely,
potentially putting the fire panel into a non-functional state and
causing serious safety issues. |
| An issue in H3C Device R365V300R004 allows a remote attacker to execute arbitrary code via the default password. NOTE: the Supplier's position is that their "product lines enforce or clearly prompt users to change any initial credentials upon first use. At most, this would be a case of misconfiguration if an administrator deliberately ignored the prompts, which is outside the scope of CVE definitions." |
| An unauthenticated SQL injection vulnerability exists in Pandora FMS version 5.0 SP2 and earlier. The mobile/index.php endpoint fails to properly sanitize user input in the loginhash_data parameter, allowing attackers to extract administrator credentials or active session tokens via crafted requests. This occurs because input is directly concatenated into an SQL query without adequate validation, enabling SQL injection. After authentication is bypassed, a second vulnerability in the File Manager component permits arbitrary PHP file uploads. The file upload functionality does not enforce MIME-type or file extension restrictions, allowing authenticated users to upload web shells into a publicly accessible directory and achieve remote code execution. |
| A hardcoded decryption key in Thinkware Cloud APK v4.3.46 allows attackers to access sensitive data and execute arbitrary commands with elevated privileges. |
| Ever Traduora 0.20.0 and below is vulnerable to Privilege Escalation due to the use of a hard-coded JWT signing key. |
| The WorkExaminer Professional server installation comes with an FTP server that is used to receive the client logs on TCP port 12304. An attacker with network access to this port can use weak hardcoded credentials to login to the FTP server and modify or read data, log files and gain remote code execution as NT Authority\SYSTEM on the server by exchanging accessible service binaries in the WorkExaminer installation directory (e.g. "C:\Program File (x86)\Work Examiner Professional Server"). |
| Use of hard-coded credentials issue exists in Ricoh Streamline NX PC Client ver.3.7.2 and earlier. If this vulnerability is exploited, an attacker may obtain LocalSystem Account of the PC where the product is installed. As a result, unintended operations may be performed on the PC. |
| An unauthenticated remote attacker can use the hard-coded credentials to access the SmartSPS devices with high privileges.
|
| Multiple hardcoded credentials have been identified, which are allowed to sign-in to the exos 9300 datapoint server running on port 1004 and 1005. This server is used for relaying status information from and to the Access Managers. This information, among other things, is used to graphically visualize open doors and alerts. However, controlling the Access Managers via this interface is also possible.
To send and receive status information, authentication is necessary. The Kaba exos 9300 application contains hard-coded credentials for four different users, which are allowed to login to the datapoint server and receive as well as send information, including commands to open arbitrary doors. |
| This vulnerability exists in ZKTeco WL20 due to hard-coded MQTT credentials and endpoints stored in plaintext within the device firmware. An attacker with physical access could exploit this vulnerability by extracting the firmware and analyzing the binary data to retrieve the hard-coded MQTT credentials and endpoints from the targeted device.
Successful exploitation of this vulnerability could allow the attacker to gain unauthorized access to the MQTT broker and manipulate the communications of the targeted device. |
| ui/pref/ProxyPrefView.java in weasis-core in Weasis 4.5.1 has a hardcoded key for symmetric encryption of proxy credentials. |
| Quantum StorNext Web GUI API before 7.2.4 grants access to internal StorNext configuration and unauthorized modification of some software configuration parameters via undocumented user credentials. This affects StorNext RYO before 7.2.4, StorNext Xcellis Workflow Director before 7.2.4, and ActiveScale Cold Storage. |
| An OEM IP camera manufactured by Shenzhen Liandian Communication Technology LTD exposes a Telnet service (port 23) with undocumented, default credentials. The Telnet service is enabled by default and is not disclosed or configurable via the device’s web interface or user manual. An attacker with network access can authenticate using default credentials and gain root-level shell access to the device. The affected firmware version is AppFHE1_V1.0.6.0 (Kernel: KerFHE1_PTZ_WIFI_V3.1.1, Hardware: HwFHE1_WF6_PTZ_WIFI_20201218). No official fix or firmware update is available, and the vendor could not be contacted. This vulnerability allows for remote code execution and privilege escalation. |
| IBM Sterling Connect:Direct for UNIX Container 6.3.0.0 through 6.3.0.6 Interim Fix 016, and 6.4.0.0 through 6.4.0.3 Interim Fix 019 IBM® Sterling Connect:Direct for UNIX contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. |
| Use of Hard-coded Credentials vulnerability in GoodWe Technologies Co., Ltd. GW1500‑XS allows anyone in physical proximity to the device to fully access the web interface of the inverter via Wi‑Fi.This issue affects GW1500‑XS: 1.1.2.1. |
| A vulnerability has been found in Tenda i24, 4G03 Pro, 4G05, 4G08, G0-8G-PoE, Nova MW5G and TEG5328F up to 65.10.15.6. Affected is an unknown function of the component Shadow File. Such manipulation with the input Fireitup leads to hard-coded credentials. An attack has to be approached locally. The exploit has been disclosed to the public and may be used. |