Search Results (9227 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-45770 1 Redhat 5 Enterprise Linux, Rhel Aus, Rhel E4s and 2 more 2026-04-15 4.4 Medium
A vulnerability was found in Performance Co-Pilot (PCP). This flaw can only be exploited if an attacker has access to a compromised PCP system account. The issue is related to the pmpost tool, which is used to log messages in the system. Under certain conditions, it runs with high-level privileges.
CVE-2024-45857 1 Cleanlab 1 Cleanlab 2026-04-15 7.8 High
Deserialization of untrusted data can occur in versions 2.4.0 or newer of the Cleanlab project, enabling a maliciously crafted datalab.pkl file to run arbitrary code on an end user’s system when the data directory is loaded.
CVE-2024-47072 2 Redhat, X-stream 4 Build Keycloak, Jboss Data Grid, Ocp Tools and 1 more 2026-04-15 7.5 High
XStream is a simple library to serialize objects to XML and back again. This vulnerability may allow a remote attacker to terminate the application with a stack overflow error resulting in a denial of service only by manipulating the processed input stream when XStream is configured to use the BinaryStreamDriver. XStream 1.4.21 has been patched to detect the manipulation in the binary input stream causing the the stack overflow and raises an InputManipulationException instead. Users are advised to upgrade. Users unable to upgrade may catch the StackOverflowError in the client code calling XStream if XStream is configured to use the BinaryStreamDriver.
CVE-2024-47081 2026-04-15 5.3 Medium
Requests is a HTTP library. Due to a URL parsing issue, Requests releases prior to 2.32.4 may leak .netrc credentials to third parties for specific maliciously-crafted URLs. Users should upgrade to version 2.32.4 to receive a fix. For older versions of Requests, use of the .netrc file can be disabled with `trust_env=False` on one's Requests Session.
CVE-2024-47142 2026-04-15 N/A
AIPHONE IXG SYSTEM IXG-2C7 firmware Ver.2.03 and earlier and IXG-2C7-L firmware Ver.2.03 and earlier contain an issue with insufficiently protected credentials, which may allow a network-adjacent authenticated attacker to perform unintended operations.
CVE-2024-4733 1 Plainware 1 Shiftcontroller 2026-04-15 7.5 High
The ShiftController Employee Shift Scheduling plugin is vulnerable to PHP Object Injection via deserialization of untrusted input via the `hc3_session`-cookie in versions up to, and including, 4.9.57. This makes it possible for an authenticated attacker with contributor access-level or above to inject a PHP Object. No POP chain is present in the vulnerable plugin. If a POP chain is present via an additional plugin or theme installed on the target system, it could allow the attacker to delete arbitrary files, retrieve sensitive data, or execute code.
CVE-2024-47579 2026-04-15 6.8 Medium
An attacker authenticated as an administrator can use an exposed webservice to upload or download a custom PDF font file on the system server. Using the upload functionality to copy an internal file into a font file and subsequently using the download functionality to retrieve that file allows the attacker to read any file on the server with no effect on integrity or availability
CVE-2024-47580 1 Sap 1 Netweaver 2026-04-15 6.8 Medium
An attacker authenticated as an administrator can use an exposed webservice to create a PDF with an embedded attachment. By specifying the file to be an internal server file and subsequently downloading the generated PDF, the attacker can read any file on the server with no effect on integrity or availability.
CVE-2024-47588 2026-04-15 4.7 Medium
In SAP NetWeaver Java (Software Update Manager 1.1), under certain conditions when a software upgrade encounters errors, credentials are written in plaintext to a log file. An attacker with local access to the server, authenticated as a non-administrative user, can acquire the credentials from the logs. This leads to a high impact on confidentiality, with no impact on integrity or availability.
CVE-2024-47971 2026-04-15 6.5 Medium
Improper error handling in firmware of some SSD DC Products may allow an attacker to enable denial of service.
CVE-2024-48206 1 Chainer 1 Chainer 2026-04-15 9.8 Critical
A Deserialization of Untrusted Data vulnerability in chainer v7.8.1.post1 leads to execution of arbitrary code.
CVE-2024-4836 2026-04-15 7.5 High
Web services managed by Edito CMS (Content Management System) in versions from 3.5 through 3.25 leak sensitive data as they allow downloading configuration files by an unauthenticated user. The issue in versions 3.5 - 3.25 was removed in releases which dates from 10th of January 2014. Higher versions were never affected.
CVE-2024-4838 2026-04-15 7.5 High
The ConvertPlus plugin for WordPress is vulnerable to PHP Object Injection in all versions up to, and including, 3.5.26 via deserialization of untrusted input from the 'settings_encoded' attribute of the 'smile_modal' shortcode. This makes it possible for authenticated attackers, with contributor-level access and above, to inject a PHP Object. No POP chain is present in the vulnerable plugin. If a POP chain is present via an additional plugin or theme installed on the target system, it could allow the attacker to delete arbitrary files, retrieve sensitive data, or execute code.
CVE-2024-48852 2026-04-15 9.4 Critical
Insertion of Sensitive Information into Log File vulnerability observed in FLEXON. Some information may be improperly disclosed through https access. This issue affects FLXEON through <= 9.3.4.
CVE-2024-52940 1 Anydesk 1 Anydesk 2026-04-15 7.5 High
AnyDesk through 8.1.0 on Windows, when Allow Direct Connections is enabled, inadvertently exposes a public IP address within network traffic. The attacker must know the victim's AnyDesk ID.
CVE-2024-53247 1 Splunk 2 Splunk Enterprise, Splunk Secure Gateway 2026-04-15 8.8 High
In Splunk Enterprise versions below 9.3.2, 9.2.4, and 9.1.7, and versions below 3.4.261 and 3.7.13 of the Splunk Secure Gateway app on Splunk Cloud Platform, a low-privileged user that does not hold the “admin“ or “power“ Splunk roles could perform a Remote Code Execution (RCE).
CVE-2024-53544 2026-04-15 9.8 Critical
NovaCHRON Zeitsysteme GmbH & Co. KG Smart Time Plus v8.x to v8.6 was discovered to contain a SQL injection vulnerability via the getCookieNames method in the smarttimeplus/MySQLConnection endpoint.
CVE-2024-53649 2026-04-15 6.5 Medium
A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V9.80), SIPROTEC 5 6MD85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 6MD86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 6MD89 (CP300) (All versions >= V7.80 < V9.68), SIPROTEC 5 6MU85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7KE85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SA82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SA82 (CP150) (All versions < V9.80), SIPROTEC 5 7SA86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SA87 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SD82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SD82 (CP150) (All versions < V9.80), SIPROTEC 5 7SD86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SD87 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SJ81 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.80), SIPROTEC 5 7SJ82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.80), SIPROTEC 5 7SJ85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SJ86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SK82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SK82 (CP150) (All versions < V9.80), SIPROTEC 5 7SK85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SL82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SL82 (CP150) (All versions < V9.80), SIPROTEC 5 7SL86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SL87 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SS85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7ST85 (CP300) (All versions < V9.68), SIPROTEC 5 7ST86 (CP300) (All versions < V9.80), SIPROTEC 5 7SX82 (CP150) (All versions < V9.80), SIPROTEC 5 7SX85 (CP300) (All versions < V9.80), SIPROTEC 5 7SY82 (CP150) (All versions < V9.80), SIPROTEC 5 7UM85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7UT82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7UT82 (CP150) (All versions < V9.80), SIPROTEC 5 7UT85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7UT86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7UT87 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7VE85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7VK87 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7VU85 (CP300) (All versions < V9.80), SIPROTEC 5 Compact 7SX800 (CP050) (All versions < V9.80). Affected devices do not properly limit the path accessible via their webserver. This could allow an authenticated remote attacker to read arbitrary files from the filesystem of affected devices.
CVE-2024-53832 2026-04-15 4.6 Medium
A vulnerability has been identified in CPCI85 Central Processing/Communication (All versions < V05.30). The affected devices contain a secure element which is connected via an unencrypted SPI bus. This could allow an attacker with physical access to the SPI bus to observe the password used for the secure element authentication, and then use the secure element as an oracle to decrypt all encrypted update files.
CVE-2024-56074 2026-04-15 5.5 Medium
gitingest before 9996a06 mishandles symbolic links that point outside of the base directory.