Search Results (1374 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-8175 1 Codesys 18 Control For Beaglebone Sl, Control For Empc-a\/imx6 Sl, Control For Iot2000 Sl and 15 more 2026-04-15 7.5 High
An unauthenticated remote attacker can causes the CODESYS web server to access invalid memory which results in a DoS.
CVE-2024-53984 2026-04-15 4.3 Medium
Nanopb is a small code-size Protocol Buffers implementation. When the compile time option PB_ENABLE_MALLOC is enabled, the message contains at least one field with FT_POINTER field type, custom stream callback is used with unknown stream length. and the pb_decode_ex() function is used with flag PB_DECODE_DELIMITED, then the pb_decode_ex() function does not automatically call pb_release(), like is done for other failure cases. This could lead to memory leak and potential denial-of-service. This vulnerability is fixed in 0.4.9.1.
CVE-2024-53916 1 Openstack 1 Neutron 2026-04-15 7.5 High
In OpenStack Neutron before 25.0.1, neutron/extensions/tagging.py can use an incorrect ID during policy enforcement. It does not apply the proper policy check for changing network tags. An unprivileged tenant is able to change (add and clear) tags on network objects that do not belong to the tenant, and this action is not subjected to the proper policy authorization check. This affects 23 before 23.2.1, 24 before 24.0.2, and 25 before 25.0.1.
CVE-2024-53432 1 Point Cloud Library 1 Pcl 2026-04-15 7.5 High
While parsing certain malformed PLY files, PCL version 1.14.1 crashes due to an uncaught std::out_of_range exception in PCLPointCloud2::at. This issue could potentially be exploited to cause a denial-of-service (DoS) attack when processing untrusted PLY files.
CVE-2025-9998 1 Arcinfo 1 Pcvue 2026-04-15 N/A
The sequence of packets received by a Networking server are not correctly checked. An attacker could exploit this vulnerability to send specially crafted messages to force the application to stop.
CVE-2025-1718 2026-04-15 6.5 Medium
An authenticated user with file access privilege via FTP access can cause the Relion 670/650 and SAM600-IO series device to reboot due to improper disk space management.
CVE-2025-9437 1 Rockwellautomation 1 Armorstart Aop 2026-04-15 N/A
A security issue exists within the Studio 5000 Logix Designer add-on profile (AOP) for the ArmorStart Classic distributed motor controller, resulting in denial-of-service. This vulnerability is possible due to the input of invalid values into Component Object Model (COM) methods.
CVE-2023-28910 2026-04-15 8 High
A specific flaw exists within the Bluetooth stack of the MIB3 infotainment system. The issue results from the disabled abortion flag eventually leading to bypassing assertion functions. The vulnerability was originally discovered in Skoda Superb III car with MIB3 infotainment unit OEM part number 3V0035820. The list of affected MIB3 OEM part numbers is provided in the referenced resources.
CVE-2025-59530 1 Quic-go Project 1 Quic-go 2026-04-15 7.5 High
quic-go is an implementation of the QUIC protocol in Go. In versions prior to 0.49.0, 0.54.1, and 0.55.0, a misbehaving or malicious server can cause a denial-of-service (DoS) attack on the quic-go client by triggering an assertion failure, leading to a process crash. This requires no authentication and can be exploited during the handshake phase. This was observed in the wild with certain server implementations. quic-go needs to be able to handle misbehaving server implementations, including those that prematurely send a HANDSHAKE_DONE frame. Versions 0.49.0, 0.54.1, and 0.55.0 discard Initial keys when receiving a HANDSHAKE_DONE frame, thereby correctly handling premature HANDSHAKE_DONE frames.
CVE-2024-24257 2026-04-15 7.5 High
An issue in skteco.com Central Control Attendance Machine web management platform v.3.0 allows an attacker to obtain sensitive information via a crafted script to the csl/user component.
CVE-2025-5922 1 Tsplus 1 Tsplus Remote Access 2026-04-15 N/A
Access to TSplus Remote Access Admin Tool is restricted to administrators (unless "Disable UAC" option is enabled) and requires a PIN code. In versions below v18.40.6.17 the PIN's hash is stored in a system registry accessible to regular users, making it possible to perform a brute-force attack using rainbow tables, since the hash is not salted. LTS (Long-Term Support) versions also received patches in v17.2025.6.27 and v16.2025.6.27 releases.
CVE-2025-58354 1 Katacontainers 1 Kata-containers 2026-04-15 7.1 High
Kata Containers is an open source project focusing on a standard implementation of lightweight Virtual Machines (VMs) that perform like containers. In Kata Containers versions from 3.20.0 and before, a malicious host can circumvent initdata verification. On TDX systems running confidential guests, a malicious host can selectively fail IO operations to skip initdata verification. This allows an attacker to launch arbitrary workloads while being able to attest successfully to Trustee impersonating any benign workload. This issue has been patched in Kata Containers version 3.21.0.
CVE-2024-2502 2026-04-15 2 Low
An application can be configured to block boot attempts after consecutive tamper resets are detected, which may not occur as expected. This is possible because the TAMPERRSTCAUSE register may not be properly updated when a level 4 tamper event (a tamper reset) occurs. This impacts Series 2 HSE-SVH devices, including xG23B, xG24B, xG25B, and xG28B, but does not impact xG21B. To mitigate this issue, upgrade to SE Firmware version 2.2.6 or later.
CVE-2025-54811 1 Openplcproject 2 Openplc V3, Openplc V3 Firmware 2026-04-15 7.1 High
OpenPLC_V3 has a vulnerability in the enipThread function that occurs due to the lack of a return value. This leads to a crash when the server loop ends and execution hits an illegal ud2 instruction. This issue can be triggered remotely without authentication by starting the same server multiple times or if the server exits unexpectedly. The vulnerability allows an attacker to cause a Denial of Service (DoS) against the PLC runtime, stopping any PC started remotely without authentication. This results in the PLC process crashing and halting all automation or control logic managed by OpenPLC.
CVE-2025-48886 2026-04-15 4.8 Medium
Hydra is a layer-two scalability solution for Cardano. Prior to version 0.22.0, the process assumes L1 event finality and does not consider failed transactions. Currently, Cardano L1 is monitored for certain events which are necessary for state progression. At the moment, Hydra considers those events as finalized as soon as they are recognized by the node participants making such transactions the target of re-org attacks. The system does not currently consider the fact that failed transactions on the Cardano L1 can indeed appear in blocks because these transactions are so infrequent. This issue has been patched in version 0.22.0.
CVE-2025-43864 2026-04-15 7.5 High
React Router is a router for React. Starting in version 7.2.0 and prior to version 7.5.2, it is possible to force an application to switch to SPA mode by adding a header to the request. If the application uses SSR and is forced to switch to SPA, this causes an error that completely corrupts the page. If a cache system is in place, this allows the response containing the error to be cached, resulting in a cache poisoning that strongly impacts the availability of the application. This issue has been patched in version 7.5.2.
CVE-2025-41241 1 Vmware 4 Cloud Foundation, Telco Cloud Infrastructure, Telco Cloud Platform and 1 more 2026-04-15 4.4 Medium
VMware vCenter contains a denial-of-service vulnerability. A malicious actor who is authenticated through vCenter and has permission to perform API calls for guest OS customisation may trigger this vulnerability to create a denial-of-service condition.
CVE-2025-41222 2026-04-15 5.3 Medium
A vulnerability has been identified in RUGGEDCOM i800 (All versions), RUGGEDCOM i801 (All versions), RUGGEDCOM i802 (All versions), RUGGEDCOM i803 (All versions), RUGGEDCOM M2100 (All versions), RUGGEDCOM M2200 (All versions), RUGGEDCOM M969 (All versions), RUGGEDCOM RMC30 (All versions), RUGGEDCOM RMC8388 V4.X (All versions), RUGGEDCOM RMC8388 V5.X (All versions < V5.10.0), RUGGEDCOM RP110 (All versions), RUGGEDCOM RS1600 (All versions), RUGGEDCOM RS1600F (All versions), RUGGEDCOM RS1600T (All versions), RUGGEDCOM RS400 (All versions), RUGGEDCOM RS401 (All versions), RUGGEDCOM RS416 (All versions), RUGGEDCOM RS416P (All versions), RUGGEDCOM RS416Pv2 V4.X (All versions), RUGGEDCOM RS416Pv2 V5.X (All versions < V5.10.0), RUGGEDCOM RS416v2 V4.X (All versions), RUGGEDCOM RS416v2 V5.X (All versions < V5.10.0), RUGGEDCOM RS8000 (All versions), RUGGEDCOM RS8000A (All versions), RUGGEDCOM RS8000H (All versions), RUGGEDCOM RS8000T (All versions), RUGGEDCOM RS900 (All versions), RUGGEDCOM RS900 (32M) V4.X (All versions), RUGGEDCOM RS900 (32M) V5.X (All versions < V5.10.0), RUGGEDCOM RS900G (All versions), RUGGEDCOM RS900G (32M) V4.X (All versions), RUGGEDCOM RS900G (32M) V5.X (All versions < V5.10.0), RUGGEDCOM RS900GP (All versions), RUGGEDCOM RS900L (All versions), RUGGEDCOM RS900M-GETS-C01 (All versions), RUGGEDCOM RS900M-GETS-XX (All versions), RUGGEDCOM RS900M-STND-C01 (All versions), RUGGEDCOM RS900M-STND-XX (All versions), RUGGEDCOM RS900W (All versions), RUGGEDCOM RS910 (All versions), RUGGEDCOM RS910L (All versions), RUGGEDCOM RS910W (All versions), RUGGEDCOM RS920L (All versions), RUGGEDCOM RS920W (All versions), RUGGEDCOM RS930L (All versions), RUGGEDCOM RS930W (All versions), RUGGEDCOM RS940G (All versions), RUGGEDCOM RS969 (All versions), RUGGEDCOM RSG2100 (All versions), RUGGEDCOM RSG2100 (32M) V4.X (All versions), RUGGEDCOM RSG2100 (32M) V5.X (All versions < V5.10.0), RUGGEDCOM RSG2100P (All versions), RUGGEDCOM RSG2100P (32M) V4.X (All versions), RUGGEDCOM RSG2100P (32M) V5.X (All versions < V5.10.0), RUGGEDCOM RSG2200 (All versions), RUGGEDCOM RSG2288 V4.X (All versions), RUGGEDCOM RSG2288 V5.X (All versions < V5.10.0), RUGGEDCOM RSG2300 V4.X (All versions), RUGGEDCOM RSG2300 V5.X (All versions < V5.10.0), RUGGEDCOM RSG2300P V4.X (All versions), RUGGEDCOM RSG2300P V5.X (All versions < V5.10.0), RUGGEDCOM RSG2488 V4.X (All versions), RUGGEDCOM RSG2488 V5.X (All versions < V5.10.0), RUGGEDCOM RSG907R (All versions < V5.10.0), RUGGEDCOM RSG908C (All versions < V5.10.0), RUGGEDCOM RSG909R (All versions < V5.10.0), RUGGEDCOM RSG910C (All versions < V5.10.0), RUGGEDCOM RSG920P V4.X (All versions), RUGGEDCOM RSG920P V5.X (All versions < V5.10.0), RUGGEDCOM RSL910 (All versions < V5.10.0), RUGGEDCOM RST2228 (All versions < V5.10.0), RUGGEDCOM RST2228P (All versions < V5.10.0), RUGGEDCOM RST916C (All versions < V5.10.0), RUGGEDCOM RST916P (All versions < V5.10.0). Affected devices do not properly handle malformed TLS handshake messages. This could allow an attacker with network access to the webserver to cause a denial of service resulting in the web server and the device to crash.
CVE-2024-34694 1 Lnbits 1 Lnbits 2026-04-15 8.1 High
LNbits is a Lightning wallet and accounts system. Paying invoices in Eclair that do not get settled within the internal timeout (about 30s) lead to a payment being considered failed, even though it may still be in flight. This vulnerability can lead to a total loss of funds for the node backend. This vulnerability is fixed in 0.12.6.
CVE-2024-41886 2026-04-15 N/A
Team ENVY, a Security Research TEAM has found a flaw that allows for a remote code execution on the NVR. An attacker could inject malformed data into url input parameters to reboot the NVR. The manufacturer has released patch firmware for the flaw, please refer to the manufacturer's report for details and workarounds.