| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A vulnerability classified as problematic was found in SAFECAM X300 up to 20250611. This vulnerability affects unknown code of the component FTP Service. The manipulation leads to use of default credentials. Access to the local network is required for this attack to succeed. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| A vulnerability was identified in TRENDnet TI-G160i, TI-PG102i and TPL-430AP up to 20250724. This affects an unknown part of the component SSH Service. The manipulation leads to use of default credentials. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The real existence of this vulnerability is still doubted at the moment. The vendor explains: "For product TI-PG102i and TI-G160i, by default, the product's remote management options are all disabled. The root account is for troubleshooting purpose and the password is encrypted. However, we will remove the root account from the next firmware release. For product TPL-430AP, the initial setup process requires user to set the password for the management GUI. Once that was done, the default password will be invalid." |
| Longse NVR (Network Video Recorder) model NVR3608PGE2W, as well as products based on this device, create a WiFi network with a default password.
A user is neither advised to change it during the installation process, nor such a need is described in the manual. As the cameras from the same kit connect automatically, it is very probable for the default password to be left unchanged. |
| IO-1020 Micro ELD web server uses a default password for authentication.
|
| Authentication credentials leakage vulnerability in Hitachi Ops Center Analyzer viewpoint.This issue affects Hitachi Ops Center Analyzer viewpoint: from 10.0.0-00 before 11.0.4-00. |
| IO-1020 Micro ELD uses a default WIFI password that could allow an adjacent attacker to connect to the device.
|
| Default credentials are used in the above listed BD Diagnostic Solutions products. If exploited, threat actors may be able to access, modify or delete data, including sensitive information such as protected health information (PHI) and personally identifiable information (PII). Exploitation of this vulnerability may allow an attacker to shut down or otherwise impact the availability of the system. Note: BD Synapsys™ Informatics
Solution is only in scope of
this vulnerability when
installed on a NUC server. BD Synapsys™
Informatics Solution installed
on a customer-provided virtual machine or on the BD Kiestra™ SCU hardware is
not in scope. |
| A vulnerability was found in China Mobile P22g-CIac, ZXWT-MIG-P4G4V, ZXWT-MIG-P8G8V, GT3200-4G4P and GT3200-8G8P up to 20250305. It has been rated as critical. This issue affects some unknown processing of the component CLI su Command Handler. The manipulation leads to use of default credentials. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| Use of Default Cryptographic Key in the hardware for some Intel(R) Pentium(R) Processor Silver Series, Intel(R) Celeron(R) Processor J Series, Intel(R) Celeron(R) Processor N Series may allow an escalation of privilege. Hardware reverse engineer adversary with a privileged user combined with a high complexity attack may enable escalation of privilege. This result may potentially occur via physical access when attack requirements are present with special internal knowledge and requires no user interaction. The potential vulnerability may impact the confidentiality (high), integrity (none) and availability (none) of the vulnerable system, resulting in subsequent system confidentiality (high), integrity (high) and availability (none) impacts. |
| Ilevia EVE X1 Server firmware versions ≤ 4.7.18.0.eden contain a use of default credentials vulnerability that allows an unauthenticated attacker to obtain remote access. Ilevia has declined to service this vulnerability, and recommends that customers not expose port 8080 to the internet. |
| Use of Default Credentials, Hard-coded Credentials vulnerability in C2SGlobalSettings.dll in
Milner ImageDirector Capture on Windows allows decryption of document archive files using credentials decrypted with hard-coded application encryption key.
This issue affects ImageDirector Capture: from 7.0.9.0 before 7.6.3.25808. |
| Multiple services of the DUT as well as different scopes of the same service reuse the same credentials. |
| PTZOptics and possibly other ValueHD-based pan-tilt-zoom cameras use default, shared credentials for the administrative web interface. |
| Default credential in install package in ABB ASPECT; NEXUS Series; MATRIX Series version 3.07 allows attacker to login to product instances wrongly configured. |
| Airship AI Acropolis includes a default administrative account that uses the same credentials on every installation. Instances of Airship AI that do not change this account password are vulnerable to a remote attacker logging in and gaining the privileges of this account. Fixed in 10.2.35, 11.0.21, and 11.1.9. |
| The Thermo Fisher Torrent Suite Django application 5.18.1 has weak default credentials, which are stored as fixtures for the Django ORM API. The ionadmin user account can be used to authenticate to default deployments with the password ionadmin. The user guide recommends changing default credentials; however, a password change policy for default administrative accounts is not enforced. Many deployments may retain default credentials, in which case an attacker is likely to be able to successfully authenticate with administrative privileges. |
| A vulnerability has been identified in SIMATIC CN 4100 (All versions < V2.7). The "intermediate installation" system state of the affected application uses default credential with admin privileges. An attacker could use the credentials to gain complete control of the affected device. |
| Default credentials on the Web Interface of Evolution Controller 2.x allows anyone to log in to the server directly to perform administrative functions. Upon installation or upon first login, the application does not ask the user to change the password. There is no warning or prompt to ask the user to change the default password. |
| A security issue was discovered in the Kubernetes Image Builder versions <= v0.1.37 where default credentials are enabled during the image build process. Virtual machine images built using the Proxmox provider do not disable these default credentials, and nodes using the resulting images may be accessible via these default credentials. The credentials can be used to gain root access. Kubernetes clusters are only affected if their nodes use VM images created via the Image Builder project with its Proxmox provider. |
| The Four-Faith router models F3x24 and F3x36 are affected by an operating system (OS) command injection vulnerability. At least firmware version 2.0 allows authenticated and remote attackers to execute arbitrary OS commands over HTTP when modifying the system time via apply.cgi. Additionally, this firmware version has default credentials which, if not changed, would effectively change this vulnerability into an unauthenticated and remote OS command execution issue. |