| ESCAM QD-900 WIFI HD cameras contain an unauthenticated configuration disclosure vulnerability in the /web/cgi-bin/hi3510/backup.cgi endpoint. The endpoint allows remote download of a compressed configuration backup without requiring authentication or authorization. The exposed backup can include administrative credentials and other sensitive device settings, enabling an unauthenticated remote attacker to obtain information that may facilitate further compromise of the camera or connected network. |
| Lua apps can be deployed, removed, started, reloaded or stopped without authorization via
AppManager. This allows an attacker to remove legitimate apps creating a DoS attack, read and write
files or load apps that use all features of the product available to a customer. |
| Reolink Video Doorbell WiFi DB_566128M5MP_W allows root shell access through an unsecured UART/serial console. An attacker with physical access can connect to the exposed interface and execute arbitrary commands with root privileges. NOTE: this is disputed by the Supplier because of "certain restrictions on users privately connecting serial port cables" and because "the root user has a password and it meets the requirements of password security complexity." |
| A local privilege escalation vulnerability exists in Agnitum Outpost Internet Security 8.1 that allows an unprivileged user to execute arbitrary code with SYSTEM privileges. The flaw resides in the acs.exe component, which exposes a named pipe that accepts unauthenticated commands. By exploiting a directory traversal weakness in the pipe protocol, an attacker can instruct the service to load a malicious DLL from a user-controlled location. The DLL is then executed in the context of the privileged service. |
| Unitree Go2, G1, H1, and B2 devices through 2025-09-20 accept any handshake secret with the unitree substring. |
| Due to improper BLE security configurations on the device's GATT server, an adjacent unauthenticated attacker can read and write device control commands through the mobile app service wich could render the device unusable. |
| General Industrial Controls Lynx+ Gateway is missing critical authentication in the embedded web server which
could allow an attacker to send GET requests to obtain sensitive device
information. |
| Improper authentication vulnerability in exists in multiple printers and scanners which implement Web Based Management provided by BROTHER INDUSTRIES, LTD. If this vulnerability is exploited, a network-adjacent user who can access the product may impersonate an administrative user. As for the details of affected product names, model numbers, and versions, refer to the information provided by the respective vendors listed under [References]. |
| An unauthenticated attacker can reset the board and stop transmitter
operations by sending a specially-crafted GET request to the command.cgi
gateway, resulting in a denial-of-service scenario. |
| The exos 9300 application can be used to configure Access Managers (e.g. 92xx, 9230 and 9290). The configuration is done in a graphical user interface on the dormakaba exos server. As soon as the save button is clicked in exos 9300, the whole configuration is sent to the selected Access Manager via SOAP. The SOAP request is sent without any prior authentication or authorization by default. Though authentication and authorization can be configured using IPsec for 92xx-K5 devices and mTLS for 92xx-K7 devices, it is not enabled by default and must therefore be activated with additional steps.
This insecure default allows an attacker with network level access to completely control the whole environment. An attacker is for example easily able to conduct the following tasks without prior authentication:
- Re-configure Access Managers (e.g. remove alarming system requirements)
- Freely re-configure the inputs and outputs
- Open all connected doors permanently
- Open all doors for a defined time interval
- Change the admin password
- and many more
Network level access can be gained due to an insufficient network segmentation as well as missing LAN firewalls. Devices with an insecure configuration have been identified to be directly exposed to the internet. |
| On the exos 9300 server, a SOAP API is reachable on port 8002. This API does not require any authentication prior to sending requests. Therefore, network access to the exos server allows e.g. the creation of arbitrary access log events as well as querying the 2FA PINs associated with the enrolled chip cards. |
| An unauthenticated remote attacker can gain access to the cloud API due to a lack of authentication for a critical function in the affected devices. Availability is not affected. |
| An unauthenticated OS command injection vulnerability exists within Xdebug versions 2.5.5 and earlier, a PHP debugging extension developed by Derick Rethans. When remote debugging is enabled, Xdebug listens on port 9000 and accepts debugger protocol commands without authentication. An attacker can send a crafted eval command over this interface to execute arbitrary PHP code, which may invoke system-level functions such as system() or passthru(). This results in full compromise of the host under the privileges of the web server user. |
| Dover Fueling Solutions ProGauge MagLink LX Consoles expose an undocumented and unauthenticated target communication framework (TCF) interface on a specific port. Files can be created, deleted, or modified, potentially leading to remote code execution. |
| An unauthenticated remote attacker may use a missing authentication for critical function vulnerability to reboot or erase the affected devices resulting in data loss and/or a DoS. |
| An unauthenticated remote attacker may use the devices traffic capture without authentication to grab plaintext administrative credentials. |
| A vulnerability has been identified in Perfect Harmony GH180 (All versions >= V8.0 < V8.3.3 with NXGPro+ controller manufactured between April 2020 to April 2025). The maintenance connection of affected devices fails to protect access to the device's control unit configuration. This could allow an attacker with physical access to the maintenance connection's door port to perform arbitrary configuration changes. |
| Certain Anpviz products allow unauthenticated users to modify or disable camera related settings such as microphone volume, speaker volume, LED lighting, NTP, motion detection, etc. This affects IPC-D250, IPC-D260, IPC-B850, IPC-D850, IPC-D350, IPC-D3150, IPC-D4250, IPC-D380, IPC-D880, IPC-D280, IPC-D3180, MC800N, YM500L, YM800N_N2, YMF50B, YM800SV2, YM500L8, and YM200E10 firmware v3.2.2.2 and lower and possibly more vendors/models of IP camera. |
| A low privileged remote attacker may modify the configuration of the CODESYS V3 service through a missing authentication vulnerability which could lead to full system access and/or DoS. |
| A low privileged remote attacker may modify the boot mode configuration setup of the device, leading to modification of the firmware upgrade process or a denial-of-service attack. |