Search Results (377282 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-36529 2026-04-15 7.2 High
An OS command injection issue exists in multiple versions of TB-eye network recorders and AHD recorders. If this vulnerability is exploited, an arbitrary OS command may be executed by an attacker who is logging in to the device.
CVE-2025-36535 1 Automationdirect 1 Mb Gateway 2026-04-15 10 Critical
The embedded web server lacks authentication and access controls, allowing unrestricted remote access. This could lead to configuration changes, operational disruption, or arbitrary code execution depending on the environment and exposed functionality.
CVE-2025-36537 1 Teamviewer 2 Full Client, Host 2026-04-15 7 High
Incorrect Permission Assignment for Critical Resource in the TeamViewer Client (Full and Host) of TeamViewer Remote and Tensor prior Version 15.67 on Windows allows a local unprivileged user to trigger arbitrary file deletion with SYSTEM privileges via leveraging the MSI rollback mechanism. The vulnerability only applies to the Remote Management features: Backup, Monitoring, and Patch Management.
CVE-2025-36539 2026-04-15 6.5 Medium
AVEVA PI Data Archive products are vulnerable to an uncaught exception that, if exploited, could allow an authenticated user to shut down certain necessary PI Data Archive subsystems, resulting in a denial of service.
CVE-2025-36553 2 Broadcom, Dell 2 Bcm5820x, Controlvault3 2026-04-15 8.8 High
A buffer overflow vulnerability exists in the CvManager functionality of Dell ControlVault3 prior to 5.15.14.19 and Dell ControlVault3 Plus prior to 6.2.36.47. A specially crafted ControlVault API call can lead to memory corruption. An attacker can issue an api call to trigger this vulnerability.
CVE-2025-36558 2026-04-15 6.1 Medium
KUNBUS PiCtory version 2.11.1 and earlier are vulnerable to a cross-site-scripting attack via the sso_token used for authentication. If an attacker provides the user with a PiCtory URL containing an HTML script as an sso_token, that script will reply to the user and be executed.
CVE-2025-3659 2026-04-15 N/A
Improper authentication handling was identified in a set of HTTP POST requests affecting the following product families: * Digi PortServer TS - prior to and including 82000747_AA, build date 06/17/2022 * Digi One SP/Digi One SP IA/Digi One IA - prior to and including 82000774_Z, build date 10/19/2020 * Digi One IAP – prior to and including 82000770 Z, build date 10/19/2020 A specially crafted POST request to the device’s web interface may allow an unauthenticated attacker to modify configuration settings.
CVE-2025-36597 2 Dell, Emc 3 Avamar Server, Powerprotect Dp Series Appliance (idpa), Avamar Virtual Edition 2026-04-15 4.7 Medium
Dell Avamar, versions prior to 19.12 with patch 338905, contains an Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability in the Security. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to information disclosure.
CVE-2025-36598 1 Dell 2 Avamar Virtual Edition, Powerprotect Dp Series Appliance (idpa) 2026-04-15 6.5 Medium
Dell Avamar, versions prior to 19.12 with patch 338905, contains an Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability in the Security. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to upload malicious files.
CVE-2025-36636 1 Tenable 1 Security Center 2026-04-15 4.3 Medium
In Tenable Security Center versions prior to 6.7.0, an improper access control vulnerability exists where an authenticated user could access areas outside of their authorized scope.
CVE-2025-36756 1 Solax 1 Solax Cloud 2026-04-15 N/A
A problem with missing authorization on SolaX Cloud platform allows taking over any SolaX solarpanel inverter of which the serial number is known.
CVE-2025-36640 2 Microsoft, Tenable 2 Windows, Nessus Agent 2026-04-15 8.8 High
A vulnerability has been identified in the installation/uninstallation of the Nessus Agent Tray App on Windows Hosts which could lead to escalation of privileges.
CVE-2025-36729 1 Racom 1 M!dge 2026-04-15 7.2 High
A non-primary administrator user with admin rights to the web interface but without shell access permissions can display configuration of the device including the master admin password. This vulnerability also allows the user to give themselves shell access with the root gid.
CVE-2025-36730 1 Windsurf 1 Windsurf 2026-04-15 N/A
A prompt injection vulnerability exists in Windsurft version 1.10.7 in Write mode using SWE-1 model. It is possible to create a file name that will be appended to the user prompt causing Windsurf to follow its instructions.
CVE-2025-36757 1 Solax 1 Solax Cloud 2026-04-15 N/A
It is possible to bypass the administrator login screen on SolaX Cloud. An attacker could use parameter tampering to bypass the login screen and gain limited access to the system.
CVE-2025-36758 1 Solax 1 Solax Cloud 2026-04-15 N/A
It is possible to bypass the clipping level of authentication attempts in SolaX Cloud through the use of the 'Forgot Password' functionality as an oracle.
CVE-2025-36751 1 Growatt 2 Mic3300tl-x, Shinelan-x 2026-04-15 N/A
Encryption is missing on the configuration interface for Growatt ShineLan-X and MIC 3300TL-X. This allows an attacker with access to the network to intercept and potentially manipulate communication requests between the inverter and its cloud endpoint.
CVE-2025-36754 1 Growatt 1 Shinelan-x 2026-04-15 N/A
The authentication mechanism on web interface is not properly implemented. It is possible to bypass authentication checks by crafting a post request with new settings since there is no session token or authentication in place. This would allow an attacker for instance to point the device to an arbitrary address for domain name resolution to e.g. facililitate a man-in-the-middle (MitM) attack.
CVE-2025-36755 1 Cleverdisplay 1 Blueone 2026-04-15 N/A
The CleverDisplay BlueOne hardware player is designed with its USB interfaces physically enclosed and inaccessible under normal operating conditions. Researchers demonstrated that, after cicumventing the device’s protective enclosure, it was possible to connect a USB keyboard and press ESC during boot to access the BIOS setup interface. BIOS settings could be viewed but not modified. This behavior slightly increases the attack surface by exposing internal system information (CWE-1244) once the enclosure is removed, but does not allow integrity or availability compromise under standard or tested configurations.
CVE-2025-36759 1 Solax 1 Solax Cloud 2026-04-15 N/A
Through the provision of user names, SolaX Cloud will suggest (similar) user accounts and thereby leak sensitive information such as user email addresses and phone numbers.