| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| The exos 9300 application can be used to configure Access Managers (e.g. 92xx, 9230 and 9290). The configuration is done in a graphical user interface on the dormakaba exos server. As soon as the save button is clicked in exos 9300, the whole configuration is sent to the selected Access Manager via SOAP. The SOAP request is sent without any prior authentication or authorization by default. Though authentication and authorization can be configured using IPsec for 92xx-K5 devices and mTLS for 92xx-K7 devices, it is not enabled by default and must therefore be activated with additional steps.
This insecure default allows an attacker with network level access to completely control the whole environment. An attacker is for example easily able to conduct the following tasks without prior authentication:
- Re-configure Access Managers (e.g. remove alarming system requirements)
- Freely re-configure the inputs and outputs
- Open all connected doors permanently
- Open all doors for a defined time interval
- Change the admin password
- and many more
Network level access can be gained due to an insufficient network segmentation as well as missing LAN firewalls. Devices with an insecure configuration have been identified to be directly exposed to the internet. |
| On the exos 9300 server, a SOAP API is reachable on port 8002. This API does not require any authentication prior to sending requests. Therefore, network access to the exos server allows e.g. the creation of arbitrary access log events as well as querying the 2FA PINs associated with the enrolled chip cards. |
| A vulnerability was found in eGauge EG3000 Energy Monitor 3.6.3. It has been classified as problematic. This affects an unknown part of the component Setting Handler. The manipulation leads to missing authentication. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| A vulnerability was found in Papendorf SOL Connect Center 3.3.0.0 and classified as problematic. Affected by this issue is some unknown functionality of the component Web Interface. The manipulation leads to missing authentication. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| A vulnerability was found in Tenda TDSEE App up to 1.7.12. It has been declared as problematic. Affected by this vulnerability is an unknown functionality of the file /app/ConfirmSmsCode of the component Password Reset Confirmation Code Handler. The manipulation leads to improper restriction of excessive authentication attempts. The attack can be launched remotely. The complexity of an attack is rather high. The exploitation appears to be difficult. The exploit has been disclosed to the public and may be used. Upgrading to version 1.7.15 is able to address this issue. It is recommended to upgrade the affected component. |
| General Industrial Controls Lynx+ Gateway
is missing critical authentication in the embedded web server which could allow an attacker to remotely reset the device. |
| Missing Authentication in the registration feature of Lablup's BackendAI allows arbitrary users to create user accounts that can access private data even when registration is disabled. |
| The MCP inspector is a developer tool for testing and debugging MCP servers. Versions of MCP Inspector below 0.14.1 are vulnerable to remote code execution due to lack of authentication between the Inspector client and proxy, allowing unauthenticated requests to launch MCP commands over stdio. Users should immediately upgrade to version 0.14.1 or later to address these vulnerabilities. |
| Vulnerability in mojofywp WP Affiliate Disclosure wp-affiliate-disclosure.This issue affects WP Affiliate Disclosure: from n/a through 1.2.6. |
| SignXML is an implementation of the W3C XML Signature standard in Python. When verifying signatures with X509 certificate validation turned off and HMAC shared secret set (`signxml.XMLVerifier.verify(require_x509=False, hmac_key=...`), versions of SignXML prior to 4.0.4 are vulnerable to a potential algorithm confusion attack. Unless the user explicitly limits the expected signature algorithms using the `signxml.XMLVerifier.verify(expect_config=...)` setting, an attacker may supply a signature unexpectedly signed with a key other than the provided HMAC key, using a different (asymmetric key) signature algorithm. Starting with SignXML 4.0.4, specifying `hmac_key` causes the set of accepted signature algorithms to be restricted to HMAC only, if not already restricted by the user. |
| DuraComm SPM-500 DP-10iN-100-MU
lacks access controls for a function that should require user authentication. This could allow an attacker to repeatedly reboot the device. |
| The privileged user could log in without sufficient credentials after enabling an application protocol. This security issue has been fixed in the latest script patch latest version of of Eaton BLSS (7.3.0.SCP004). |
| Password guessing limits could be bypassed when using LDAP authentication. |
| Lua apps can be deployed, removed, started, reloaded or stopped without authorization via
AppManager. This allows an attacker to remove legitimate apps creating a DoS attack, read and write
files or load apps that use all features of the product available to a customer. |
| A vulnerability was found in Digistar AG-30 Plus 2.6b. It has been classified as problematic. Affected is an unknown function of the component Login Page. The manipulation leads to improper restriction of excessive authentication attempts. The complexity of an attack is rather high. The exploitability is told to be difficult. The vendor was contacted early about this disclosure but did not respond in any way. |
| A missing check_access() function in the lollms_binding_infos module of the parisneo/lollms repository, version V14, allows attackers to add, modify, and remove bindings arbitrarily. This vulnerability affects the /install_binding and /reinstall_binding endpoints, among others, enabling unauthorized access and manipulation of binding settings without requiring the client_id value. |
| Certain modes of routers from Billion Electric have a Missing Authentication vulnerability, allowing unauthenticated remote attackers to directly access the specific functionality to obtain partial device information, modify the WiFi SSID, and restart the device. |
| ZF Roll Stability Support Plus (RSSPlus)
is vulnerable to an authentication bypass vulnerability targeting
deterministic RSSPlus SecurityAccess service seeds, which may allow an
attacker to remotely (proximal/adjacent with RF equipment or via pivot
from J2497 telematics devices) call diagnostic functions intended for
workshop or repair scenarios. This can impact system availability,
potentially degrading performance or erasing software, however the
vehicle remains in a safe vehicle state. |
| The devices allow access to an unprotected endpoint that allows MPFS
file system binary image upload without authentication. The MPFS2 file
system module provides a light-weight read-only file system that can be
stored in external EEPROM, external serial flash, or internal flash
program memory. This file system serves as the basis for the HTTP2 web
server module, but is also used by the SNMP module and is available to
other applications that require basic read-only storage capabilities.
This can be exploited to overwrite the flash program memory that holds
the web server's main interfaces and execute arbitrary code. |
| Missing Authentication for Critical Function vulnerability in the mobile monitoring feature of Mitsubishi Electric GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric AnalytiX versions 10.97.2 and prior, Mitsubishi Electric MobileHMI versions 10.97.2 and prior, Mitsubishi Electric IoTWorX version 10.95, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions AnalytiX versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions MobileHMI versions 10.97.2 and prior, and Mitsubishi Electric Iconics Digital Solutions IoTWorX version 10.95 allows a remote unauthenticated attacker to bypass proper authentication and log in to the system when all of the following conditions are met: (1) Active Directory is used in the security setting (2) "Automatic log in" option is enabled in the security setting (3) The IcoAnyGlass IIS Application Pool is running under an Active Directory Domain Account. (4) The IcoAnyGlass IIS Application Pool account is included in GENESIS64, ICONCIS Suite, and MC Works64 Security and has permission to log in. |