Export limit exceeded: 21830 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (21830 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2024-40893 | 1 Firewalla | 1 Box Software | 2026-04-15 | 6.8 Medium |
| Multiple authenticated operating system (OS) command injection vulnerabilities exist in Firewalla Box Software versions before 1.979. A physically close attacker that is authenticated to the Bluetooth Low-Energy (BTLE) interface can use the network configuration service to inject commands in various configuration parameters including networkConfig.Interface.Phy.Eth0.Extra.PingTestIP, networkConfig.Interface.Phy.Eth0.Extra.DNSTestDomain, and networkConfig.Interface.Phy.Eth0.Gateway6. Additionally, because the configuration can be synced to the Firewalla cloud, the attacker may be able to persist access even after hardware resets and firmware re-flashes. | ||||
| CVE-2024-31162 | 1 Asus | 1 Download Master | 2026-04-15 | 7.2 High |
| The specific function parameter of ASUS Download Master does not properly filter user input. An unauthenticated remote attacker with administrative privileges can exploit this vulnerability to execute arbitrary system commands on the device. | ||||
| CVE-2024-34013 | 1 Acronis | 1 True Image | 2026-04-15 | N/A |
| Local privilege escalation due to OS command injection vulnerability. The following products are affected: Acronis True Image (macOS) before build 41396, Acronis True Image OEM (macOS) before build 42571. | ||||
| CVE-2024-52587 | 1 Step Security | 1 Harden Runner | 2026-04-15 | 8.8 High |
| StepSecurity's Harden-Runner provides network egress filtering and runtime security for GitHub-hosted and self-hosted runners. Versions of step-security/harden-runner prior to v2.10.2 contain multiple command injection weaknesses via environment variables that could potentially be exploited under specific conditions. However, due to the current execution order of pre-steps in GitHub Actions and the placement of harden-runner as the first step in a job, the likelihood of exploitation is low as the Harden-Runner action reads the environment variable during the pre-step stage. There are no known exploits at this time. Version 2.10.2 contains a patch. | ||||
| CVE-2024-34073 | 2026-04-15 | 7.8 High | ||
| sagemaker-python-sdk is a library for training and deploying machine learning models on Amazon SageMaker. In affected versions the capture_dependencies function in `sagemaker.serve.save_retrive.version_1_0_0.save.utils` module allows for potentially unsafe Operating System (OS) Command Injection if inappropriate command is passed as the “requirements_path” parameter. This consequently may allow an unprivileged third party to cause remote code execution, denial of service, affecting both confidentiality and integrity. This issue has been addressed in version 2.214.3. Users are advised to upgrade. Users unable to upgrade should not override the “requirements_path” parameter of capture_dependencies function in `sagemaker.serve.save_retrive.version_1_0_0.save.utils`, and instead use the default value. | ||||
| CVE-2024-5241 | 2026-04-15 | 4.7 Medium | ||
| A vulnerability was found in Huashi Private Cloud CDN Live Streaming Acceleration Server up to 20240520. It has been classified as critical. Affected is an unknown function of the file /manager/ipconfig_new.php. The manipulation of the argument dev leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-265992. | ||||
| CVE-2024-52320 | 1 Planet Technology Corp | 1 Wgs-804hpt Firmware | 2026-04-15 | 9.8 Critical |
| The affected product is vulnerable to a command injection. An unauthenticated attacker could send commands through a malicious HTTP request which could result in remote code execution. | ||||
| CVE-2024-40895 | 2026-04-15 | 6.4 Medium | ||
| FFRI AMC versions 3.4.0 to 3.5.3 and some OEM products that implement/bundle FFRI AMC versions 3.4.0 to 3.5.3 allow a remote unauthenticated attacker to execute arbitrary OS commands when certain conditions are met in an environment where the notification program setting is enabled and the executable file path is set to a batch file (.bat) or command file (.cmd) extension. | ||||
| CVE-2024-52034 | 1 Myscada | 2 Mypro Manager, Mypro Runtime | 2026-04-15 | 10 Critical |
| An OS Command Injection vulnerability exists within myPRO Manager. A parameter within a command can be exploited by an unauthenticated remote attacker to inject arbitrary operating system commands. | ||||
| CVE-2024-52010 | 2026-04-15 | N/A | ||
| Zoraxy is a general purpose HTTP reverse proxy and forwarding tool. A command injection vulnerability in the Web SSH feature allows an authenticated attacker to execute arbitrary commands as root on the host. Zoraxy has a Web SSH terminal feature that allows authenticated users to connect to SSH servers from their browsers. In HandleCreateProxySession the request to create an SSH session is handled. An attacker can exploit the username variable to escape from the bash command and inject arbitrary commands into sshCommand. This is possible, because, unlike hostname and port, the username is not validated or sanitized. | ||||
| CVE-2024-30804 | 1 Asus | 1 Fan Xpert | 2026-04-15 | 9.8 Critical |
| An issue discovered in the DeviceIoControl component in ASUS Fan_Xpert before v.10013 allows an attacker to execute arbitrary code via crafted IOCTL requests. | ||||
| CVE-2024-43778 | 1 Takenaka Engineering | 9 Ahd04t-a Firmware, Ahd08t-a Firmware, Ahd16t-a Firmware and 6 more | 2026-04-15 | 8.8 High |
| OS command injection vulnerability in multiple digital video recorders provided by TAKENAKA ENGINEERING CO., LTD. allows a remote authenticated attacker to execute an arbitrary OS command on the device or alter the device settings. | ||||
| CVE-2024-43688 | 2 Openbsd, Vixie | 2 Openbsd, Cron | 2026-04-15 | 7.3 High |
| cron/entry.c in vixie cron before 9cc8ab1, as used in OpenBSD 7.4 and 7.5, allows a heap-based buffer underflow and memory corruption. NOTE: this issue was introduced during a May 2023 refactoring. | ||||
| CVE-2024-43657 | 2026-04-15 | 8.8 High | ||
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: High. However, the attacker will need a (low privilege) account to gain access to the action.exe CGI binary and upload the crafted firmware file, or convince a user with such access to upload it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). | ||||
| CVE-2024-43656 | 2026-04-15 | 8.8 High | ||
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – It might be difficult for an attacker to identify the file structure of the <redated> directory, and then modify the backup to add a new CGI script in the correct directory. Furthermore, the attacker will need an account to restore the settings backup, or convince a user with such access to upload a modified backup file. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). | ||||
| CVE-2024-43655 | 2026-04-15 | N/A | ||
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The attacker will first need to find the name of the script, and needs a (low privilege) account to gain access to the script, or convince a user with such access to execute a request to it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). | ||||
| CVE-2024-43654 | 2026-04-15 | 8.8 High | ||
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects all Iocharger AC EV charger models on a firmware version before 25010801. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). | ||||
| CVE-2024-43653 | 2026-04-15 | 8.8 High | ||
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). | ||||
| CVE-2024-43652 | 2026-04-15 | 8.8 High | ||
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. | ||||
| CVE-2024-43650 | 2026-04-15 | N/A | ||
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects firmware versions before 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: The attack can be executed over any network connection serving the web interface (AV:N). There are no additional measures that need to be circumvented (AC:L) or attack preconditions (AT:N). THe attack is privileged, but the level does not matter (PR:L) and does not require user interaction (UI:N). Attack leads to full system compromised (VC:H/VI:H/VA:H) and compromised devices can be used to "pivot" to other networks that should be unreachable (SC:L/SI:L/SA:H). Because this an EV charger using high power, there is a potential safety impact (S:P). The attack can be automated (AU:Y). | ||||